Setting Up a Micronics U1000 Ultrasonic Flow Meter

Overview

Recommended Settings:

Click on the Enter Button

  • A password prompt should show:
    • Password:  71360
  • Hit enter:
    • Select 
  • Pipe material:
    • Flow:
      • Gallons
    • Flow units:
      • Gallons per minute
  • Instrument fluid:
    • Water
  • Pulse output:
    • Pulse type:
      • Volume
  • Volume per pulse:
    • 1 gallon
  • Pulse width:
    • 50 ms (default)
  • Calibration:
    • Damping time :
      • 20 s
    • Zero-cutoff: .
      • 23 f/s
    • Zero offset:
      • 0 f/s
    • Calibration factor:
      • 1
  • Totals:
    • Select totals:
      • On
    • Reset totals:
      • No
    • Inside diameter of the pipe
      • See Chart Below

Note:
If we see no pulses and an exclamation point!!  this means that the flow is reverse flow.  